Our Products

Hydrant Valve

63 mm Single/Double Hydrant Valve Gun Metal/Stainless Steel As Per IS 5290 with ISI Mark and Warranty certificate. H.P. tested to 21 kgf/cm2 (body) and 14 kgf/cm2 (seat). Flow 900 lpm (min) at 7 kgf/cm2.

Branch Pipe

63mm Short Branch Pipe With Nozzle Gun Metal/Stainless Steel As per IS 903 with ISI Mark and Warranty certificate. H.P. tested to 21 kgf/cm2 for 2.5 minutes.

CP/RRL Hose

Cotton Synthetic Fibre/ Rubberized Fabric Reinforced (ISI) with Coupling Complete Set. Burst Pressure 36kg/cm2 (530 PSI), Proof Pressure 22kg/cm2 (320 PSI), Working Pressure 18 Kg/cm2 (260 PSI).

Hose Reel Drum

Hose Reel (Swinging type), as per IS: 884, made of M.S. construction, having Rubber/ PVC hose of 1”/ ¾“ dia. of 30/36 mtrs. length, and fitted with PVC/Gunmetal/SS Shut off nozzle. The Hose Reel shall meet the performance requirements as given in IS:884 Hose Reel Tubing: Rubber/PVC (braided).

Hose Box

Superior grade MS material with glass fittng. Available in different sizes. Painting color red. Require low maintenance. Customiozed thickness and FRP also available on order.

Fire Brigade Inlet

63 mm size Gunmetal/SS Male Instantaneous inlets (with NRV) 80/100/150 mm size flanged outlet, suitable for connection to Dry Riser piping. Hydrostatic Pressure Test 21 gf/cm2 for 2.5 minutes. Working Pressure 7 Kgf/cm2

Monitors

Water/Foam Monitors with Carbon Steel body duly hot dip galvanized having 63MM Barrel Size & 75mm/100mm flanged inlet, with a flow capacity of 1750lp/2580/3500@7kg/cm2 as per IS: – 8442

ABC Type Fire Extinguisher

Powder: Mono Ammonium Phosphate Discharge Time: 8 Sec. Class A, B, C & electrically started Fire. ISI Approved IS 15683:2006. Service Pressure (Ps): 15 bars. Pressure tested: 35 bar

CO2 Portable Fire Extinguisher

Discharge Time 12 Sec. Applicable on Class B, C and electrically started Fire. Extinguisher shells are 100% hydro tested to excess of 250 bar. ISI Approved IS 15683:2006 BIS & PESO approved.

fire-safety-solutions

Mechanical Foam

Foam Fire Extinguishers provide a fast, powerful means of tackling flammable liquids. Applicable against Class ‘A’ hazards such as wood, cloth, trash, and other materials that leave an ash. Extinguisher shells are 100% factory hydro tested to excess of 35 bar. ISI Approved IS 5683:2006

Water Type Fire Extinguisher

Applicable against Class ‘A’ hazards such as wood, cloth, trash, and other materials that
leave an ash. Extinguisher shells are 100% factory hydro tested to excess of 35 bar under the vigilance of Engineers. Fire Rating- 4A, ISI Approved IS 15683:2006

Clean Agent/ Suppression System

HFC/FE: Electrically nonconductive, non corrosive, colorless and non-residual. Suitable for Class A, B, C, and electrical fires, low toxicity. Ideal for protecting delicate electronic equipments. ISI Approved IS 15683:2006.
NOVEC: Clean agent Automatic Triggering Self actuating system.

Fire Ball

Safe for use on Class A (ordinary combustibles), Class B (Flammable liquid) spills, Class C (energized electrical fires) Self Activating – Simply throw or roll into a fire and it will self-activate within 3 – 5 seconds. Long Shelf Life of 5 Years.

Conventional Panels

Advance Micro controller based Fire Alarm Panel 2 TO 64 Zones 16×2 character LCD Display Mains, A. C. Fail, fuse, Charging, Rev. Batt. Indication. Compatible with any make smoke & heat detector.

Conventional Fire Bus

Inbuilt MCB & Hooter with single zone Fire alarm Panel. Battery Charger & Battery backup facility. Compatible with up to 8 to 10 smoke detector (any make). System healthy, fire, A.C. fail indications. AC Power:220v AC, 50Hz ± 10%.

Manual Call Point

Body: MS/PVC. Compatibility with any conventional fire Alarm System. Duel LED on front Steady RED LED at fire condition Operating voltage: 24V DC.

Hooter

Body: MS/PVC. Compatibility with any conventional fire Alarm System Operating voltage: 24 VDC Current Consumption (Normal /Fire): 350mA@ 24 VDC.

Wireline Smoke Detector

Power supply polarity free input. Infrared photoelectric sensor.Dustproof, mothproof, anti-light interference design. Stainless steel shield in chamber, anti-RF1 (20V/m -1GFIz) MCU processing, eliminate false alarm Flashing LED power indicator. Remote LED indicator output.

Battery operated Smoke Detector

Test Button – Test unit’s electronic circuitry horn and battery function Blinking power indicator – Confirms unit is receiving power Battery Operated (9V Battery Included) -Protects even during a power outage Low Battery Indicator – Smoke alarm will chirp in the event of a low battery. Missing battery Guard – Cover resists closing unless battery is inside. Tamper Resist Locking Screw – Helps deters alarm tampering or theft.

SPRINKLER SYSTEM

Pendent

All hazards. Response: Standard and Quick Temp. Rating: 165°F (74°C) U, 212°F (100°C), 280°F (138°C). UL and C-UL Listed. FM, and LPCB Approved.

Sidewall

Light hazard / Ordinary hazard. Response: Standard and Quick. Temp. Rating: 165°F (74°C) U, 212°F (100°C), 280°F (138°C) UL and C-UL Listed. FM, and LPCB Approved.

Upright

Light hazard / Ordinary hazard. Response: Standard & Quick Temp. Rating:165°F (74°C) U, 212°F (100°C), 280°F (138°C). UL and C-UL Listed. FM, and LPCB Approved.

Concealed Sprinkler

Light hazard/Ordinary hazard. Concealed in an enclosed escutcheon plate with flat cover. Separable, two-piece design of the mounting cup and cover. Internally threaded closure with 1/2″ (12,7 mm) of adjustment, Available with optional dust and air sea.

Sprinkler Flexible Drop

Flexible Hose: AISI 304 Stainless
steel. Inlet connection: DN25,
Male BSP or NPT thread. Outlet connection: 1/2” or 3/4” Female NPT thread internal diameter: 25mm or 28mm . Hose length : 700mm (28”), 1000mm (40”), 1200mm (47”), 1500mm (59”), 1800 (71”).

Medium Velocity Nozzle

Brass/SS construction. Size 1/2″ BSPT or NPT. Open orifice design used in deluge water spray system. Non-automatic fixed pattern, external deflector. Solid cone discharge. K-factor(Metric) – 18, 22, 30, 35, 41, 51, 64, 79, 91 & 102.

Curtain Spray nozzle, made of Brass (forged), with ½” male threaded inlet (¾” threaded inlet option available). The nozzle K factors (SI) available include 23/ 30/ 37/ 45/ 53/ 72, while spray will be an approximate semicircular pattern.